Type E Flange Insulation Gasket Kits
Product Description
Product Detail
Type E Flange Insulation Gasket Kit Supplier — Full-Face Coverage, Bolt-Hole Located, Bulk & OEM Isolation Sets
Full-Face Coverage — Closing the External Bridge by Geometry
Same OD as the Flange, Bolt Holes for Positioning
Type E is not a raised-face gasket. The central gasket has the same outside diameter as the flange and precision-cut bolt holes. It covers the entire flange face — not just the raised portion. There is no exposed edge at the flange OD for conductive debris — rust scale, water, graphite dust — to bridge the gap between the two flanges. That is the primary difference from Type F: Type F relies on the raised face only and requires tape wrap to close the exposed OD; Type E closes it by geometry.
Type E vs Type F vs Type D — Three Geometries, Three Installation Logics
| Dimension | Type E (this page) | Type F | Type D |
|---|---|---|---|
| Flange facing | Full-face (FF) or RF — covers entire face | Raised-face (RF) only | RTJ ring groove |
| Bolt holes in central gasket | Precision-cut | None | None |
| Centering mechanism | Bolt holes sleeve onto bolts; OD covers flange | OD slightly less than bolt circle ID — automatic | Wedges into groove; groove walls constrain |
| External bridge protection | Geometric — OD covers flange | Requires tape wrap to close exposed edge | Requires tape wrap to close groove edge |
| Torque pattern | Star pattern: 30% → 60% → 100% | Star pattern; centering via OD | Star pattern + alignment pins |
Bolt Holes Are the Positioning Mechanism — Not a Convenience
The bolt holes are not a manufacturing artifact. They are the positioning mechanism. The gasket is located on the bolts before the flange closes, which ensures the full-face coverage stays concentric with the flange OD. If the bolt holes are misaligned, the gasket can shift and leave an exposed sliver at the OD — the same failure mode the full-face geometry is meant to prevent. That is why the installation procedure is specific: insert insulating sleeves into the bolt holes, locate the gasket on the sleeves, then torque in a star pattern. For raised-face flanges where no bolt holes are present in the gasket, see Type F Drop-in insulation kits.
Carrier Material Choice — Phenolic Is the Default, G10/G11 Go Higher
| Carrier | Dielectric (V/mil) | Compressive (psi) | Max Temp (°C) | Best For | Avoid When |
|---|---|---|---|---|---|
| Plain Phenolic (default) | 500 | 25,000 | +104 | Standard FF/RF flanges, cost-sensitive projects, sealing priority | Service above 104°C |
| Neo-faced Phenolic | 500 | 25,000 | +79 | Rough flange face requiring a soft sealing layer | Service above 79°C |
| G-10 Epoxy Glass | 550 | 50,000 | +138 | Higher temperature, higher bolt load, lower water absorption | Cost-sensitive standard service |
| G-11 Epoxy Glass | 550 | 50,000+ | +176 | Higher temperature ceiling | Cost-sensitive standard service |
The trade-off is temperature and cost. Plain phenolic gives −54°C to +104°C and the lowest material cost. G10 doubles the compressive strength and raises the temperature ceiling to +138°C, at a higher price. For a soft sealing face on a rough flange surface, the neoprene faced phenolic option drops the upper limit to +79°C. For RTJ flanges where the gasket must seat inside a groove, see Type D RTJ insulation kits.
Technical Data — Plain Phenolic Carrier (Type E)
| Dielectric strength | 500 V/mil |
|---|---|
| Compressive strength | 25,000 psi |
| Water absorption | 1.6% |
| Insulation resistance | 40,000 Meg Ohms |
| Flexural strength | 22,500 psi |
| Operating temperature | −54°C to +104°C (−65°F to +220°F) |
| Standard thickness | 1/8″ (3.2 mm) |
| Pressure class | ANSI Class 300 standard; confirm for higher ratings |
Installation — Torque Sequence and Tape Wrap
Star-Pattern Torque
Tighten bolts in a cross (or star) pattern with 30% of recommended torque, then 60%, then 100%. Retorque after thermal cycling. The star pattern keeps the gasket concentric during compression; a one-pass torque can shift the gasket and expose an edge.
Tape Wrap — Secondary Barrier
Full-face coverage closes the primary external bridge path. Tape wrap around the flange OD is still recommended as a secondary barrier against contamination during service. It is not a replacement for correct gasket geometry.
Kit Contents and Factory Traceability
Each Type E kit includes the full-face phenolic central gasket with precision-cut bolt holes, insulating sleeves, insulating washers and steel back-up washers. Kaxite operates an ISO 9001 quality system; kits are supplied with material certificates and dimensional inspection records. Dielectric strength is verified on the central gasket before shipment. Third-party inspection (SGS, BV, Intertek) can be coordinated. For the full range of insulation kit types, see flange insulation gasket kits.
MOQ, Lead Time and OEM Packaging
Standard MOQ is 10 sets; standard lead time is 7–15 days for standard FF/RF kits. Custom carrier materials (G10/G11) and non-standard sizes are quoted separately with confirmed timing. OEM marking and private-label packaging are available. For very critical service beyond the standard phenolic range, see the VCS flange insulation gasket kit.
Buyer FAQ
- What is the difference between Type E and Type F insulation kits?
- Type E covers the entire flange face with the same OD as the flange and precision-cut bolt holes; it closes the external bridge path by geometry. Type F sits only on the raised face, has no bolt holes, and requires tape wrap to close the exposed OD. The flange facing and the need for full-face coverage determine the type.
- How do the bolt holes locate the gasket — and what happens if they misalign?
- The gasket is located on the bolts before the flange closes, keeping the full-face coverage concentric with the flange OD. If the bolt holes are misaligned, the gasket can shift and leave an exposed sliver at the OD. That is why the installation procedure requires inserting sleeves first, then locating the gasket, then torquing in a star pattern.
- What pressure class and temperature can a Type E phenolic kit handle?
- ANSI Class 300 is the standard pressure reference for a plain phenolic Type E kit. Plain phenolic covers −54°C to +104°C; a neoprene sealing face drops the upper limit to +79°C. For higher temperature, G10 (+138°C) and G11 (+176°C) carriers are available.
- Is tape wrap still required on Type E?
- Yes, as a secondary barrier. Full-face coverage closes the primary external bridge path by geometry, but tape wrap around the flange OD is still recommended against contamination during service. It does not replace correct gasket geometry.
- What is the MOQ and lead time for Type E FF kits?
- MOQ is 10 sets for standard FF/RF kits; standard lead time is 7–15 days. G10/G11 carriers and custom sizes are quoted separately with confirmed timing.
- Can you supply Type E in G10 or G11 for higher temperature?
- Yes. G10 raises the temperature ceiling to +138°C and compressive strength to 50,000 psi; G11 raises it further to +176°C. State the service temperature and bolt load at inquiry so the correct carrier is quoted.
Send your full-face flange size, pressure class, carrier material (phenolic / G10 / G11) and service temperature. Engineering team confirms the kit construction, MOQ and lead time.
Request Type E Kit Quotation